Omicron Driver Download For Windows 10

Drivers & Download World-class scanning technology demands world-class scanner support. That’s why Fujitsu has made it easy for you to find support information and key scanner downloads for all of its scanner models. Find installation guides, technical data, parts numbers for scanner consumables, and more via the menu below. Free omicron ied scout download software at UpdateStar - The integrated Nero Scout technology provides fast access to all media files including advanced keyword search options Duplicates CDs and DVD Creates audio CDs, DVD-Video, MP3/ WMA CD/DVDs, Video/Super Video CDs, CD Extras, Mixed Mode.

  1. Omron's user-friendly, fully-integrated software solutions are designed for easy set up and manageability of the most complex automated applications.
  2. This download installs the Intel® Graphics Driver for 6th Gen. Driver: Windows 10, 64-bit. Windows 8.1, 64-bit. Windows 7, 32-bit. Windows 7, 64-bit. 15. Latest:: Intel® Graphics Driver for Windows® 10 15.404th Gen This download installs version 15.40.7.64.4279 of the Intel® Graphics Driver for Windows® 10, 64-bit.
  3. Find OmicronLab software downloads at CNET Download.com, the most comprehensive source for safe, trusted, and spyware-free downloads on the Web.

By downloading and installing the software from OMICRON Lab, you agree to the download terms and conditions as well as the End User License Agreement (EULA). Please read the respective documents before downloading and installing OMICRON Lab software.

If you do not agree with these agreements and conditions, do not download the software.

Bode Analyzer Suite

Note: Bode Analyzer Suite V3.X and V2.X cannot be installed at the same time on a PC! (This also applies to the automation interface)
Bode Analyzer Suite installs the graphical user interface (GUI) as well as the automation interface (AI).

Bode Analyzer Suite V3.23
Full installer
32 bit & 64 bit

(192 MB)

Download

Bode Analyzer Suite
V3.23
32 bit systems only

(121 MB)

Download

Bode Analyzer Suite V3.23
64 bit systems only

(121 MB)

Download
CharacteristicMinimum Configuration
ProcessorIntel Core-I Dual-Core (or similar)
Memory (RAM)2 GB, 4 GB recommended
Graphics resolutionSuper VGA (1024x768)
higher resolution recommended
Graphics cardDirectX 11 with Direct2D support
USB interfaceUSB 2.0 or higher
Operating systemWindows 10 required for BAS 3.24 or newer
SoftwareBode Analyzer Suite 3.00 or newer

Automation Interface

Attention: BAS V3.X comes with a completely new Automation Interface! If you have developed an automated solution with a previous version of the Bode Analyzer Suite you will have to apply some changes if you want to use the BAS V3.X!

If you need help, please contact us at [email protected]

Bode Automation Interface V3.23
Automation interface only (32 bit & 64 bit)

(150 MB)

Download

The new Automation Interface 3.X brings several advantages to you:

  • Compatibility with the new Bode 100 Hardware-Revision 2
  • Use the predefined measurement modes of Bode Analyzer Suite
  • Control more than one Bode 100 from one PC
  • Perform faster measurements (especially single-point measurements)
  • Use events to build real-time applications
  • Fully compatible with 32 bit and 64 bit Microsoft Windows systems
  • Directly access the Automation Interface from .NET
  • Access from multiple programming languages via COM

To learn more about the new Automation Interface 3.X, check out the Automation Interface reference at:
www.omicron-lab.com/BodeAutomationInterfaceHelp

In addition there is a LabVIEW® instrument driver available for download from www.ni.com.

***!!! Software on this page does not support the current Bode 100 Revision 2 device !!!***

The Automation Interface has totally changed from BAS 2.43SR1 to BAS V3.X.

This version is an old legacy version of the BAS and is not recommended for new designs!

We do not recommend to download this old version except you really need the old Automation Interface structure!

Important: This version is not compatible with the current Bode 100 Revision 2 hardware!

CD Bode Analyzer Suite v2.43 SR1
Full Version

(173 MB)

Download

Bode Redist Package v2.43 SR1
Automation Interface only

(36 MB)

Download

Older versions required?

Please contact us [email protected]

V3.24 (2021-02-10)

Bode Analyzer Suite 3.24 brings several new features that allow you to:

  • Copy trace data from one measurement file to another using drag & drop
  • Paste trace data from a spreadsheet program into Bode Analyzer Suite
  • Use the improved stability margin calculation and Fres-Q calculation
  • Start the new experimental SCPI server to control the Bode Automation Interface using SCPI commands
  • Benefit from several bugfixes (see: Version Information)

Bode Automation Interface 3.24

  • Now comes with an experimental SCPI server that features the full Automation Interface functionality (no GUI functions)
  • With Bode Analyzer Suite 3.24 we have switched to the .NET Core framework which allows you to run the Automation Interface on Linux

Bode Analyzer Suite 3.23 brings some important bug-fixes:

  • Details see: Version Information

Bode Automation Interface:

  • Fixed bug causing NaN in ExternalCoupler measurements (see Version Information)

V3.22 (2019-12-04)

Bode Analyzer Suite 3.22 brings several new features that allow you to:

  • Use more than 2 cursors; add and remove cursors in the cursor table
  • Re-order cursors in the cursor table and add more than one delta-cursor
  • Copy the entire cursor table to the clipboard and paste it in e.g. a spreadsheet program
  • Use cursor tracking to automatically find a maximum, minimum or zero on a curve after every sweep has completed
  • Use Port-Extension to shift the reference plane mathematically along a transmission line during reflection measurement
  • Export calibration / correction data for the use in the Automation Interface
  • Recognize corrupted data due to overload and clipping via the improved overload warnings in the chart
  • See the influence of your calibration/correction on the measurement even after the measurement has been completed
  • Use the improved PDF reporting
  • Benefit from several bugfixes (see: Version Information)

Bode Automation Interface:

  • Changed the file-loading of calibration files
  • Added port-extension feature
  • Updated USB driver for Bode 100 Revision 2 devices to latest version from manufacturer
  • Several minor bugfixes

Automation Interface:

  • Added 'Remove(double frequency)' and 'Clear()' to the Shaping functions to allow modifying shaped measurements

Bugfixes and details can be found in: Version information

V3.20 (2018-10-30)

  • Nichols chart shows open-loop to closed-loop relationship
  • Stability margin calculation automatically shows gain margin, phase margin and crossover frequency
  • Receiver level indicators bigger and shown during calibration
  • Dark-Theme introduced
  • Add more than 2 traces & re-order traces and memory traces using drag and drop
  • Configure your preferred default axis view in the options (one axis per chart)
  • Quick access toolbar offers access to start and stop on any ribbon
  • Management service is uninstalled and not used anymore
  • 'Copy all trace data' is available in chart context menu
  • Faster file-loading and startup-time
  • Fres-Q feature can use phase to find a resonance
  • Trace “Eye-Icon” allows to quickly switch off the measurement data to show only memory curves

Automation Interface:

  • ConfigureCustomSweep(): Frequency points now by ref because of troubles with 'VBA'
  • LabVIEW: ConfigureHardwareSetup.vi and GetHardwareSetup.vi offer only valid properties. Use <CTR+B> to 'remove broken wires' after updating to 3.20
  • Improved stability when controlling multiple Bode devices in parallel

Bugfixes and details can be found in: Version information

  • Averaging feature
  • Smith-chart in fixed-frequency measurements
  • Several bug-fixes (see: Version information)

V3.11 (2017-08-14)

BAS 3.11 further improves BAS 3.00 and brings new features:

  • Automatic Resonance-frequency and Q-factor calculation
    (especially for RFID and NFC measurements)
  • Link cursors to evaluate e.g. Gain slope at crossover frequency
  • Long memory names are displayed via mouse-over
  • For a detailed list of improvements and known issues, see: Version information

BAS 3.00 is a completely new Bode Analyzer Suite that brings the following improvements and new features:

  • Measure up to 50 MHz with your existing Bode 100
  • Improved work-flow especially for memory curves
  • Predefined measurement modes fitting your measurement application
  • 7 Impedance measurement modes to measure impedance from mΩ to MΩ
  • Attach cursors to memories
  • Perform Shunt-Thru and Series-Thru measurements
  • De-embed connections, probes and mounts using Open, Short and Load calibration in all impedance measurement modes
  • Perform swept or fixed frequency measurements in all modes
  • Export CSV, Excel and Touchstone files
  • Save your measurement results as a PDF print-report
  • Use multiple Bode 100 devices on one PC
  • Completely new and improved Automation Interface with COM and .NET access

V2.43 SR1 (2014-11-27)

  • Fixed issue with Warm-Up (Automation Interface)
  • Improved reaction speed of new Advanced PM Calculation
  • Release information and details
  • Source On/Off changed in Automation Interface
  • New 'Non-Invasive Phasemargin Calculation' method
  • BAS creates logfile for better customer support
  • Several performance improvements and bugfixes
Windows

V2.42 (2014-01)

  • Automatic optimizing of the sweep curve (Auto Optimize)
  • Drag & drop support for shaped level dialog
  • New bode file type with .bodex extension
  • Save and load of calibration in the Automation Interface
  • .boa file is no longer supported in the Automation Interface
  • New Automation Interface methods to increase measurement speed
  • Tg calculation to impedance/reflection measurements added
  • Unwrapped phase display improved
  • Memory trace csv export issue fixed
  • Minor bug fixes

V2.41 (2012-12)

  • Added chart annotations
  • Multiple memory traces added
  • Data+Memory, scaling algorithm
  • Copy chart to clipboard can include cursor table
  • Options dialog redesigned
  • Cursor color and style can be changed
  • Font size for documentation purpose can be changed
  • Improved 125% and 150% readability
  • Multiple instances of the Bode Analyzer Suite can be started
  • Toolbars can be switched on and off
  • Automation Interface structure redesigned
  • LabVIEW library adapted to the new Automation Interface structure
  • Minor Bug fixes

V2.33 SR5 (2012-07)

  • Internal Calibration is stored in the Automation Interface
  • Resolved impedance measurement issue from 5-20 kHz
  • Minor bug fixes
  • Cursor position stored in Bode file
  • Nyquist Diagram added
  • New Cursor functions Jump to Zero, Jump to Value and Jump to next Value added
  • Migration to .net Framework 4.0
  • Minor bug fixes

V2.32 (2011-07)

  • New commenting feature added for all measurement modes
  • Improved Calibration time out handling for low receiver bandwidths
  • Some cosmetic bug fixes
  • Phase Margin Calculation for non-invasive stability measurement of power supplies added
  • Logarithmic scaling and improved zoom possibilities for shaped level setup screen added
  • Improved visibility of gridlines
  • Minor bug fixing

V2.30 SR1 (2010-10)

  • Improved Clipboard Export (better grid, better curve separation between data and memory)
  • New manual added to CD-ROM in pdf Format
  • Minor bug fixes
  • Logarithmic scaling of Y axis added
  • New Impedance Adapter mode for the use with the B-WIC and B-SMC adapters
  • RLC Q Sweep to display capacitance, inductance and Q factor in the frequency sweep mode
  • Full Speed mode - quicker measurements ad low frequencies and low receiver bandwidths
  • Averaging, Min Hold, Max Hold trace functions added
  • Selective unwrapped phase function added
  • New charting software implemented
  • Improved control of the Bode output source (on/off/auto)

V2.23 (2010-01)

  • Improved Phase performance at low frequencies
  • Data/Memory function for impedance and admittance fixed
  • Enhanced CSV Export (more data exported)
Windows
  • Unwrapped Phase mode added
  • Bode File name now shown in print report
  • Automation Interface extension:
    • External Coupler Mode support
    • Possibility to Load/Save Bode Files via Automation Interface
    • Control of Shaped Level via Automation Interface
    • Activation of Unwrapped Phase in AI
    • VSWR Mode support
    • Definition of individual frequencies for sweep now possible

V2.2 (2007-12)

  • Print Reporting added (Print out measurement results & equipment settings)
  • Export measurement data to Clipboard including equipment settings added
  • External Coupler mode for impedance measurements added
  • Shaped Level function for stability analysis of control loops added
  • Measurement Range extended down to 1 Hz
  • VSWR Mode added
  • Windows support extended to: Vista, Vista x64, Win XP x64
  • Jump to Min/Max Cursor Function added
  • some cosmetic surgeries done (Wiring Pictures, About Dialog, …)
  • OLE compatible automation interface for the integration of Bode 100 into automatic measurement setups
  • Two calibration methods:
    • User Calibration - to reach highest accuracy by calibrating every single frequency point
    • Probe Calibration - for flexible operation; allows change of frequency settings without the need of re-calibration
  • Store & retrieve Bode 100's settings, measurement results and calibration in *.Bode (XML) file format
  • Export measurement data in CSV format allows easy data processing with tools like Excel™ and MatLAB™
  • Serial and parallel equivalent circuits displayed in the impedance measurement mode
    up to 16501 measurement points supported frequency sweep mode

V1.0 (2005-03)

The historic initial version of the Bode Analyzer Suite.

User manual for Bode 100 and BAS 3.24

(10 MB)

Download

Quick Start Guide for Bode 100 and BAS 3.X

(2 MB)

Download

Bode 100 product brochure

(343 KB)

Download

If you are still using Bode Analyzer Suite 2.X, feel free to download the old user manual below.

User manual for Bode 100 and BAS 2.X

Omicron Driver Download For Windows 10 Pro

(5 MB)

Download

Lasers, Lightengines and LED Lightsources
for Life Science and Bio-Instrumentation

LuxX + Flyer

QuixX Flyer

Omicron Device Driver for Metamorph microscopy Software
32 and 64-bit Driver for Windows

Works for PhoxX, PhoxX+, LuxX, LuxX+, BrixX, LightHUB, SOLE, LEDMOD and LedHUB

Omicron Device Driver for LabVIEW laboratory software
VI´s for LabVIEW

Works for PhoxX, PhoxX+, LuxX, LuxX+ and BrixX diode lasers

The µManager microscopy software directly supports the below mentioned Omicron products.

Omicron Driver Download For Windows 10 Laptop

Please download the full Software package directly from the µManager Website.

Omicron Driver Download For Windows 10

µManager supports PhoxX, PhoxX+, LuxX, LuxX+ and BrixX diode lasers as well as LightHUB and SOLE laser combiners / laser light engines.

Comments are closed.